Dépôt numérique
RECHERCHER

Assessing the impact of renewal scenarios on the global structural state of sewer pipe networks.

Duchesne, Sophie; Bouchard, Kassandra; Toumbou, Babacar et Villeneuve, Jean-Pierre (2014). Assessing the impact of renewal scenarios on the global structural state of sewer pipe networks. Canadian Journal of Civil Engineering / Revue canadienne de génie civil , vol. 41 , nº 8. pp. 761-768. DOI: 10.1139/cjce-2014-0037.

Ce document n'est pas hébergé sur EspaceINRS.

Résumé

Le premier objectif de cet article est d’illustrer comment les modèles mathématiques simulant l’état structural des réseaux d’assainissement peuvent aider a` la planification des ressources financières nécessaires pour le maintien de l’état des réseaux d’assainissement. Son second objectif est d’évaluer et de comparer le taux de remplacement annuel qui devrait être appliqué sur quatre réseaux d’assainissement canadiens, en vue de stabiliser a` long terme leur état structural global. Les résultats montrent que les taux annuels de remplacement requis sont les mêmes pour les quatre réseaux a` l’étude, même si leur état structural global était différent avant que le remplacement débute. De plus, le taux annuel de remplacement requis est trois fois moindre lorsque l’état structural de toutes les conduites du réseau est connu, par rapport a` la situation pour laquelle l’état structural n’est connu pour aucune

Abstract

The first objective of this paper is to demonstrate how mathematical models simulating the structural state of sewer pipes can help to assess the financial resources required for the preservation of sewer networks. The second objective is to assess and compare the annual replacement rate that should be applied to four different Canadian sewer networks to stabilize their global structural state for the long term. The required annual replacement rates are similar for the four studied networks, even if their global structural states were different prior to replacement. Results also show that the required annual replacement rate is three times less if the deterioration states of all pipes in the network are known, as opposed to the case where the structural states are unknown. This demonstrates the importance of sewer pipe inspection for the planning of sewer pipe renewal.

Type de document: Article
Mots-clés libres: canadian sewers; cohorts; deterioration; inspection; planning; simulation model; stormwater; survival analysis; wastewater; réseaux d’assainissement canadiens; cohortes; deterioration; inspection; planification; modèle de simulation; eaux pluviales; analyse de survie; eaux usées
Centre: Centre Eau Terre Environnement
Date de dépôt: 29 août 2017 18:54
Dernière modification: 29 août 2017 18:54
URI: https://espace.inrs.ca/id/eprint/3573

Gestion Actions (Identification requise)

Modifier la notice Modifier la notice