Electrochemical removal of organics and oil from sawmill and ship effluents.

Drogui, Patrick; Asselin, Mélanie; Brar, Satinder Kaur; Benmoussa, Hamel et Blais, Jean-François ORCID logoORCID: https://orcid.org/0000-0003-3087-4318 (2009). Electrochemical removal of organics and oil from sawmill and ship effluents. Canadian Journal of Civil Engineering , vol. 36 , nº 3. pp. 529-539. DOI: 10.1139/L09-003.

Ce document n'est pas hébergé sur EspaceINRS.

Résumé

La présente étude a porté sur le traitement par électrocoagulation d’effluents d’usine de sciage de bois et de cales de navire. Des rendements faibles d’élimination de la DCO soluble (12,5 à 13,6%) ont été observés avec les effluents d’usine de sciage de bois en comparaison à ceux mesurés avec les effluents de cales de navire (74,7 à 77,0%). Le rendement d’élimination de la DCO soluble le plus élevé, soit 77 %, a été obtenu en configuration bipolaire en utilisant des électrodes d’Al, une intensité de courant de 0,3 A et un temps de rétention de 60 min. Une hausse rapide du pH couplée à une baisse de la DCO soluble a été notamment observée au cours des 20 premières minutes de traitement. La combinaison de l’électrocoagulation et de la floculation chimique a amélioré considérablement l’efficacité du traitement comparativement à la floculation seule et ce, avec les rendements d’élimination suivants : 86 % turbidité, 56 % DCO soluble, 69 % DCO totale, 90 % huiles et graisses, 94 % hydrocarbures (C10-C50) et 89 % DBO5.

Abstract

The present study investigates the electrocoagulation treatment of two different wastewaters, namely sawmill wastewater and ship waste effluent, charged with organic matter. Monopolar electrode configuration was studied for both types of effluents at current intensity of 2.0 A for a total treatment time of 90 min. Soluble chemical oxygen demand (CODs) removal was very low (12.5% to 13.6%) for sawmill effluent in comparison to 74.7% to 75.4% obtained for ship effluents. Thus, ship effluent was further examined in details for its treatment efficacy in terms of electrode configuration and type, current intensity, treatment time, and pH. It was observed that bipolar electrode configuration using the Al electrode at 0.3 A gave the highest CODs removal of 77%. Effluent pH increased rapidly in the initial 20 min with a concomitant decrease in CODs concentration. Electrocoagulated-flocculated ship effluent improved performance relative to simple flocculation with respective removals of 86% of turbidity, 56% of CODs; 69% of total COD (CODt), 90% of oil and grease, 94% of C10-C50 hydrocarbons and 89% of biochemical oxygen demand (BOD5). Residual Al3+ concentration in the solution followed a linear trend with treatment time. Meanwhile, the sludge production increased progressively during 60 min of treatment time. Total cost for treatment of ship effluent, including energy, electrodes, and sludge disposal fee is estimated between CAN$1.34 and CAN$2.40m–3.

Type de document: Article
Mots-clés libres: sawmill effluent; ship effluent; electrochemical treatment; electrocoagulation; flocculation; COD removal; aluminium; iron; effluent d’usine de sciage; effluent de cales de navire; traitement électrochimique; électrocoagulation; floculation; enlèvement de la DCO; aluminium; fer
Centre: Centre Eau Terre Environnement
Date de dépôt: 11 janv. 2021 14:34
Dernière modification: 18 févr. 2022 20:02