Dépôt numérique
RECHERCHER

Behavior of Energetic Materials in Ground Water at an Anti-Tank Range.

Martel, Richard ORCID logoORCID: https://orcid.org/0000-0003-4219-5582; Mailloux, Michel; Gabriel, Uta; Lefebvre, René; Thiboutot, Sonia et Ampleman, Guy (2009). Behavior of Energetic Materials in Ground Water at an Anti-Tank Range. Journal of Environmental Quality , vol. 38 , nº 1. pp. 75-92. DOI: 10.2134/jeq2007.0606.

Ce document n'est pas hébergé sur EspaceINRS.

Résumé

An environmental issue has arisen with M‐72 malfunction on anti‐tank ranges because many of these rockets break into pieces without exploding on impact, dispersing their energetic materials content on the ground surface and exposing them to transport by infiltration of rainfall and snowmelt. A case study (1998–2005) at Arnhem Anti‐Tank Range (Garrison Valcartier, Canada, in operation since the 1970s) revealed octahydro‐1,3,5,7‐tetranitro‐1,3,5,7‐tetrazocine (HMX) contamination and traces of 1,3,5‐trinitro‐1,3,5‐triazine (RDX) and 2,4,6‐trinitrotoluene (TNT) in ground water at varying concentrations, with all detected HMX concentrations below the USEPA guideline for drinking water of 400 μg L−1 An HMX mass balance on a transect perpendicular to ground water flow, about 300 m downgradient of the impact area, indicated an HMX flux of about 3 g d−1 (0.7–1 kg yr−1, 2005). The HMX mass in the impact area on the sand terrace was estimated at 7 to 10 kg (in 2005). The annual dissolved HMX flux represents about 10% of the source. The dissolved HMX plume in ground water consisted of a series of slugs, generated at each significant infiltration event. HMX is weakly retarded by sorption and is neither biotransformed nor mineralized under the aerobic conditions of the aquifer. TNT and RDX exceeded the USEPA guideline (2 μg L−1 RDX and 1 μg L−1 TNT) in three and two samples, respectively. The TNT plume was discontinuous because this compound was not always present at the ground surface. TNT is biotransformed, weakly sorbed, and not mineralized. In two wells, perchlorate associated with the propellant was found at concentrations above the Health Canada preliminary guideline of 6 μg L−1 near the firing position.

Type de document: Article
Mots-clés libres: eaux souterraines;
Centre: Centre Eau Terre Environnement
Date de dépôt: 05 août 2022 15:38
Dernière modification: 05 août 2022 15:38
URI: https://espace.inrs.ca/id/eprint/10761

Gestion Actions (Identification requise)

Modifier la notice Modifier la notice