Predictive real time control of surcharged interceptors : Impact of several control parameters.

Duchesne, Sophie; Mailhot, Alain et Villeneuve, Jean-Pierre (2003). Predictive real time control of surcharged interceptors : Impact of several control parameters. Journal of the American Water Resources Association , vol. 39 , nº 1. pp. 125-135. DOI: 10.1111/j.1752-1688.2003.tb01566.x.

Ce document n'est pas hébergé sur EspaceINRS.

Résumé

A global predictive real time control strategy minimizing overflow volumes from combined sewers during rainfall was applied to control flows entering the Marigot interceptor (Laval, Canada) for 23 rain events that occurred in this urban area during the summer of 1989. Different surcharge intensities were allowed in the sewer. The duration of the control horizon as well as the location and number of control regulators were varied to assess the impact of these parameters on total overflow volumes and on control safety. Due to the high propagation speed of flow waves in pressurized conduits, it was found that five‐ minute control horizons were sufficient to ensure control performance and safety when important surcharges were permitted in the interceptor and when the controlled regulators were located where pressurized flow occurred. It was also found that it is possible to reduce the number of controlled regulators by placing them at locations intercepting the largest volumes of water during rain periods.

Type de document: Article
Mots-clés libres: combined sewer overflows; global predictive control; control horizon; controlled regulators; rain predictions; storm water management
Centre: Centre Eau Terre Environnement
Date de dépôt: 08 janv. 2021 14:01
Dernière modification: 08 janv. 2021 14:01
URI: https://espace.inrs.ca/id/eprint/11075

Gestion Actions (Identification requise)

Modifier la notice Modifier la notice