Dépôt numérique
RECHERCHER

Performance Assessment of Horizontal Ground Heat Exchangers under a Greenhouse in Quebec, Canada.

Téléchargements

Téléchargements par mois depuis la dernière année

Plus de statistiques...

Léveillée-Dallaire, Xavier; Raymond, Jasmin ORCID logoORCID: https://orcid.org/0000-0002-7486-9185; Snæbjörnsson, Jónas Þór ORCID logoORCID: https://orcid.org/0000-0003-4391-9925; Fujii, Hikari et Langevin, Hubert (2023). Performance Assessment of Horizontal Ground Heat Exchangers under a Greenhouse in Quebec, Canada. Energies , vol. 16 , nº 15. p. 5596. DOI: 10.3390/en16155596.

[thumbnail of P4361.pdf]
Prévisualisation
PDF
Télécharger (5MB) | Prévisualisation

Résumé

Among the various approaches to agriculture, urban greenhouse farming has gained attention for its ability to address food security and disruptions to global food supply chains. However, the increasing impact of climate change and global warming necessitates sustainable methods for heating and cooling these greenhouses. In this study, we focused on the potential of slinky-coil horizontal ground heat exchangers (HGHEs) to meet the energy demands of urban greenhouses, assuming they are installed beneath the greenhouse to optimize space utilization. Climate data, an energy consumption profile for a greenhouse being designed in La Pocatière (Québec, Canada) and in-situ ground thermal properties assessments were used to build numerical models using FEFLOW and to evaluate the performance of the HGHEs simulated. Four scenarios were simulated and compared to a base case, considering the greenhouse’s maintenance of a constant temperature above an HGHE limited to the greenhouse’s dimensions. Our findings reveal that a minimum of 7.1% and 26.5% of the total heating and cooling loads of a small greenhouse (133 m2 area) can be covered by HGHEs installed at a 1.5 m depth when there is no greenhouse above. When installed under a greenhouse with a constant inside temperature of 21 °C, the coverage for heating loads increases to 22.8%, while cooling loads decrease to 24.2%. Sensitivity analysis demonstrates that the constant temperature in the greenhouse reduces the system’s reliance on surface temperature fluctuations for both heating and cooling, albeit with reduced efficiency for cooling.

Type de document: Article
Mots-clés libres: ground-source heat pump; horizontal ground heat exchangers; sustainable energy; numerical simulation; greenhouse heating systems; energy efficiency
Centre: Centre Eau Terre Environnement
Date de dépôt: 07 déc. 2023 20:40
Dernière modification: 07 déc. 2023 20:40
URI: https://espace.inrs.ca/id/eprint/13747

Gestion Actions (Identification requise)

Modifier la notice Modifier la notice